61
The [Break] dialog box is displayed. To set hardware break conditions, select [Condition] in the
[Break] dialog box to display the [Condition] page.
Figure 3.43 [Condition] Page ([Break] Dialog Box)
Up to three breakpoints can be set independently for the Break Condition hardware break
condition. In this example, set the hardware break condition for Break Condition 1.
Note: The number of hardware break conditions differs according to the product. For the
number that can be specified for each product, refer to the online help.
Highlight the first point in the [Break Condition] list box.
Click the [Edit...] button. The [Break Condition 1] dialog box is displayed.