211
Figure 6.15 [Performance 1] Dialog Box
Measurement range
One of the following ranges can be specified. This depends on the item selected for [Mode]
in the [Performance 1] dialog box.
1. From the start to the end of the user program execution (When Normal Break is
selected for [Mode])
2. From the satisfaction of the condition set in Break Condition 1 to the satisfaction of
the condition set in Break Condition 2 (When Break condition 1->2 is selected for
[Mode])
3. From the satisfaction of the condition set in Break Condition 2 to the satisfaction of
the condition set in Break Condition 1 (When Break condition 2->1 is selected for
[Mode])
(In the second and third ranges, (P) is added and displayed as Enable(P) on the [Condition]
page in the [Break] dialog box.)
For measurement errors,
The measured value includes errors.
Error will occur before or after a break.
Notes: 1. When the second and third ranges are specified, execute the user program after the
measurement start condition is set to Break Condition 1 (or Break Condition 2) and
the measurement end condition to Break Condition 2 (or Break Condition 1).
2. Step execution is not possible when Break condition 1->2 or Break condition 2->1 is
selected for the PERFORMANCE_SET command or in [Mode] of the [Performance
1] dialog box.