(3) Start Range To End Range Measurement
Figure 3.40 Start Range To End Range Measurement Settings
[Range Name]: The name of the range to be measured
[Start Range]: The start range for the Start Range To End Range Measurement
[Start Address]: Start address
[End Address]: End address
[End Range]: The end range for the Start Range To End Range Measurement
[Start Address]: Start address
[End Address]: End address
Starts measurement with a detected prefetch cycle in the specified start address range, and then stops with a
detected prefetch cycle in the specified end address range. The execution count is incremented every time the
program passes the end address range.