Renesas TM V.3.20A Spezifikationen Seite 673

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 762
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 672
Renesas Technology, Tools FAQs
Last Updated: August 5, 2004
Document Number: 04070501_e
Q.
Does the emulator system support execution of STP and WIT instructions?
A.
Support conditions for STP and WIT instructions on the emulator system differ according to the program execution method.
Operation during Program Execution
When the STP or WIT instruction is executed while the user program is running, the clock stop operation and return to the
program from the clock stop state are in the same manner as with the MCU.
Operation during Single-Step or Over-Step Execution
When the STP or WIT instruction is executed in a single-step or over-step execution, the clock is stopped in the same manner
as with the MCU. Return to the program differs according to the following return triggers.
(1)Return due to Reset
The step operation is terminated (break) at the address set in the reset vector.
(2)Return due to Interrupt
After execution of an interrupt routine, the step operation is terminated (break) at the instruction following the STP or
WIT instruction. However, if the interrupt routine is an endless loop, a time out error will occur, because the interrupt
routine cannot terminate itself.
Top of Page | Back to Previous Page
Terms of Use Privacy Policy
(C)2004 Renesas Technology Corp., All Rights Reserved.
Seitenansicht 672
1 2 ... 668 669 670 671 672 673 674 675 676 677 678 ... 761 762

Kommentare zu diesen Handbüchern

Keine Kommentare