Renesas Technology, Tools FAQs
Last Updated: July 5, 2002
Document Number: 02062002_e
Q.
I need to open the trace window in order to use the M3T-PD32R trace function, but I am unable to select the menu that would allow
me to open the trace window in M3T-PD32R.
A.
The M3T-PD32R trace window can be opened when all of the following conditions are satisfied.
The target MCU trace output pin and the emulator are connected with a trace interface cable.
The correct MCU file is selected with the MCU tab in the Init dialog that is open at the time M3T-PD32R is launched.
(For details on how to select the correct MCU file, refer to M3T-PD32R Release Note titled, "MCU file list provided with the
PD32R product".)
The "Connect" radio button is selected with the SDI Trace Cable tab in the Init dialog that is open at the time M3T-PD32R is
launched.
(If the Init dialog doesn't open when M3T-PD32R is launched, restart M3T-PD32R while pressing the Ctrl key.)
Top of Page | Back to Previous Page