Q.
I know I can specify the PD30 protect break for a consecutive 256K-byte area, but can I specify the break for more than one area at
the same time?
[Example]
00000h to 3FFFFh area
C0000h to FFFFFh area
A.
You cannot specify a protect for the above example area through the protect window or protect command. The protect break
specification of the PC4701M/PC4701HS emulator does not have this feature.
PC4701M/PC4701HS has two types of protect break:
Protect break set in 1-byte units from the BASE address within a 256K bytes area1.
Protect break set in 256K-byte units for the entire area2.
Only type #1 can be set from PD30; type #2 is used for custom commands. For more details concerning how to use these protect
breaks, please refer to the readme file.