Q.
Can PD30SIM perform the CRC code generation which M16C/62 has in its hardware function? In other words, can I use the CRC
data register and CRC input register for CRC generation?
A.
Yes, you can do so in the following way:
[Method]
Register file crc.scr with the option-load menu of the I/O window. File crc.scr is installed in product install directory
\PD30SIM\SAMPLE.
This configuration will allow you to store the CRC results in the CRC data register by simply accessing the CRC input register.
(Reference info)
Please review the CRC sample section in the PDF file (I/O Script Sample Program Introduction).