Q.
Have the contents of the following Tool News article been updated and fixed concerning PD30 V.4.00?
"Precaution on Using Time Measurement Windows in PC4701HS/PC4700H Emulators" in Tool News No.
MESCT-PC4701HS_TRGA-980716D
If the contents have not been fixed yet, do I still need to use phicount_e.exe?
A.
The problem of this time measurement function is caused by the emulator hardware. PD30 V.4.00 and newer versions have the
measurement resource selection function for time measurement functions. Therefore, you do not need to use phicount.
[Measurement Resource Selection Method]
Specify the MCU cycle in the time count resource of INIT dialog Time Page when you execute PD30. Then, input the MCU
operation clock. For example, when you use the MCU operation clock (16 MHz) in the divided-by-2 mode, you need to set 8 MHz.
For more details, please review:
PD30 V.4.00 User's Manual, p. 23, "Selection of Measurement resource of zone time measurement", and PD30 V.4.10 Release 1
Release Note, "5.13 About Time Measurement Window".