Q.
I tried to setup an event in the PD308 time measurement window. But I can't select the Fetch button, why not?
A.
The Fetch button cannot be specified as an event in PD308. To work around this, you need to use an address read detection that will
access the target code. However, in this case an event may occur due to a pre-fetch detection as well.
[Reference]
M16C/80 Series MCUs do not have a debug function for detecting a Fetch event, as indicated by the M16C/80 Series MCU
specifications. Therefore, a Fetch event cannot be specified in the H/W break or time measurement of the PD308 debug functions.
Top of Page | Back to Previous Page