Rev.2.10 Apr 14, 2006 page 363 of 378
REJ09B0124-0210
M16C/6N Group (M16C/6NK, M16C/6NM) 23. Usage Notes
Figure 23.5 When Updating Period of CAN Module Matches Access Period from CPU
fCAN
✕✕ ✕✕
CPU read signal
CPU reset signal
Updating period of
CAN module
CiSTR register
b8: State_Reset bit
i = 0, 1
0: CAN operation
mode
1: CAN reset/initial-
ization mode
: When the CAN modules State_Reset bit updating period matches the CPUs read
period, it does not enter reset mode, for the CPU read has the higher priority.
Figure 23.6 With Wait Time of 3 fCAN Before CPU Read
Figure 23.7 When Polling Period of CPU is 3 fCAN or Longer
: Updated without fail in period of 3 fCAN
CPU read signal
CPU reset signal
Updating period of
the CAN module
CiSTR register
b8: Reset state flag
Wait time
i = 0, 1
0: CAN operation
mode
1: CAN reset/initial-
ization mode
: Updated without fail in period of 4 fCAN
CPU read signal
CPU reset signal
Updating period of
the CAN module
CiSTR register
b8: State_Reset bit
4 f
CAN
i = 0, 1
0: CAN operation
mode
1: CAN reset/initial-
ization mode
: When the CAN module's State_Reset bit updating period matches the CPU's read
period, it does not enter reset mode, for the CPU read has the higher priority.