Seitenansicht 23
Usage Precautions
M3A-2114 User’s Manual (22/68)
3
3.6 About Evaluation Board
When the evaluation board does not start operation after supplied power, check the following points.
3.6.1 Contact failure of IC Socket
Oscillation or thermal expansion may cause a poor connection between microcomputers and IC socket on the
Evaluation Board. Follow the steps below.
- Screw down the top cover of IC socket with setscrews at four corners.
The tightening torque shall be 0.55Kg·cm·maximum.
Note that only one tight setscrew may cause a poor connection.
The socket included in the evaluation board uses NQPACK and HQPACK by TOKYO ELETECH CORPORATION.
For more details, visit their website at http://www.tetc.co.jp/e_tet_product.htm.
The following illustrates configuration of M3A-2114G22 (32172/32173 Group Evaluation Board).
Figure 3.6-1 Configuration of M3A-2114G22
3.6.2 Cable Connection
- Make sure the cables are connected to the evaluation board firmly.
IC socket (HQPACK)
32172/32173 group evaluation
board M3A-2114G22
Setscrews on cove
r
of IC socket
Seitenansicht 23