(4) Select [Reset Go] from the [Debug] menu. When the content of the address range changes with execution,
the updated values are red (i.e. the color that was selected in the [Foreground] and [Background] combo
boxes). Values will be displayed in black if they have not been updated or a certain period of time has
elapsed since the last update.
Figure 6.72 [Monitor] Window (during Execution)
(5) After you have finished checking the states in the [Monitor] window, select [Halt Program] from the [Debug]
menu to halt the program’s execution.