8
When the circuit is connected as shown in figure 1.4, the switches of the emulator are set as SW2
= 0 and SW3 = 1. For details, refer to section 3.8, Setting the DIP Switches, in the Debugger Part
of the SuperH
TM
Family E10A-USB Emulator User’s Manual.
SH7710
VccQ
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
2
4
6
8
12
10
14
16
18
20
22
24
26
28
30
32
34
36
VccQ
VccQ
VccQ
VccQ
AUDATA0
AUDATA2
AUDATA1
AUDATA3
TCK
TMS
AUDSYNC
N.C.
N.C.
N.C.
RESET
TDI
TDO
TRST
ASEBRKAK
GND
GND
GND
GND
(GND)
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
AUDATA0
AUDATA2
AUDATA1
AUDATA3
TCK
RESETP
TMS
TDO
TDI
TRST
ASEBRKAK
AUDCK
AUDSYNC
AUDCK
N.C.
ASEMD0
User system
H-UDI port connector
(36-pin type)
Reset signal
Pulled-up at 4.7 k or more (all)
1 k
VccQ = 3.3 V (I/O power supply)
Figure 1.4 Circuit for Connection between the H-UDI Port Connector and MPU when the
Emulator is in Use (36-Pin Type UVCC Not Connected*)
Note: When UVCC is not connected and the user system is turned off, note that the leakage
current flows from the emulator to the user system.