Renesas R8C/15 Technical Information Seite 42

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 279
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 41
R8C/14 Group, R8C/15 Group 6. Voltage Detection Circuit
Rev.2.10 Jan 19, 2006 Page 28 of 253
REJ09B0164-0210
Figure 6.4 VCA1 and VCA2 Registers
Voltage Detection Register 1
Symbol Address After Reset
(2)
VCA1
0031h 00001000b
Bit Symbol Bit Name Function RW
NOTES :
1.
2. The software reset, w atchdog timer reset and voltage monitor 2 reset do not affect this register.
VCA13
Voltage Detection 2 Signal Monitor
Flag
(1)
00
(b2-b0)
RW
0 : VCC < Vdet2
1 : VCC
Vdet2 or voltage detection 2
circuit disabled
RO
Reserved Bit
b0
0000
Set to “0”
0
b7 b6 b5 b4 b3 b2 b1
The VCA13 bit is enabled when the VCA27 bit in the VCA2 register is set to “1” (voltage detection 2 circuit enabled).
The VCA13 bit is set to “1” (VCC
Vdet 2) w hen the VCA27 bit in the VCA2 register is set to “0” (voltage detection 2
circuit disabled).
(b7-b4)
Reserved Bit Set to “0”
RW
Voltage Detection Register 2
(1)
After Reset
(4)
Symbol Address
Hardware Reset : 00h
VCA2 0032h Pow er-On Reset, Voltage Monitor 1Reset
: 01000000b
Bit Symbol Bit Name Function RW
NOTES :
1.
2.
3.
4.
b7 b6 b5 b4 b3 b2 b1 b0
000000
(b5-b0)
Reserved Bit Set to “0”
RW
VCA26
Voltage Detection 1 Enable Bit
(2)
0 : Voltage detection 1 circuit disabled
1 : Voltage detection 1 circuit enabled
RW
VCA27
Voltage Detection 2 Enable Bit
(3)
0 : Voltage detection 2 circuit disabled
1 : Voltage detection 2 circuit enabled
RW
Set the PRC3 bit in the PRCR register to “1” (w rite enable) before w riting to this register.
When using the voltage monitor 1 reset, set the VCA26 bit to “1”.
After the VCA26 bit is set from0” to “1”, the voltage detection circuit elapses for td(E-A) before starting operation.
When using the voltage monitor 2 interrupt / reset or the VCA13 bit in the VCA1 register, set the VCA27 bit to “1”.
After the VCA27 bit is from 0” to “1”, the voltage detection circuit elapses for td(E-A) before starting operation.
The software reset, w atchdog timer reset and voltage monitor 2 reset do not affect this register.
Seitenansicht 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 278 279

Kommentare zu diesen Handbüchern

Keine Kommentare