Renesas M3T-SRA74 Bedienungsanleitung Seite 165

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 177
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 164
E8a Emulator User's Manual Appendix E E8aSCP (E8a Self-Check Program)
Insert the user system interface cable into the self-check
connector with the fault
y
-insertion-
p
revention nose below.
Figure E.2 Connecting the User System Interface Cable to the Self-Check Connector
WARNING
Connecting to the Self-Check Connector:
Make sure to disconnect the USB cable from the E8a before connecting
the user system interface cable to the user-system connector or the self-
check connector of the E8a.
If the E8aSCP program is executed when the USB cable remains
connected to the E8a after ‘Disconnect’ is done from the High-
performance Embedded Workshop or Flash Development Toolkit, self-
checking will not be executed correctly. This is caused by the different
condition of the E8a pins. The E8aSCP program expects that the E8a
pins are in the condition right after starting-up the E8a, but after
‘Disconnect’ is done, they remain in the condition where the E8a is
connected to the user system.
Fully insert the user system interface cable in the self-check connector
as shown in figure E.2.
(3) Start up the host computer, and connect the E8a emulator to the USB connector of the host
computer via the USB cable provided.
REJ10J1655-0400 Rev.4.00 Page 149 of 158