M34571T2-CPE User’s Manual 3. Usage (How to Use the Emulator Debugger)
REJ10J0972-0100 Rev.1.00 February 10, 2006
Page 51 of 72
(2) Trace point setup dialog box
Opening the trace point setup dialog box
Menu Menu item Function
Debug Trace Point Setting the trace point dialog box
1. Setting the trace point dialog box
2. Address event setting window in initial state
Setting an address event
You can select one of three conditions, and you can also se
t
a pass count.
Point: Specified address
Range In: Specified address range
Range Out: Outside of specified address range
Trace point setup dialog box
You can use a combination of address event (A1 or A2) and
external trigger event (T) as a trace event.
Setting an address event
By selecting A1 or A2, the address event dialog box will be
displayed.
Setting an external trigger event
You can set edges or pass count of external trigger event.
High: Falling edge
Low: Rising edge