M16C Family PC7501 Emulator
Graphical Display of Data Trace Results
Watch items can also be added by dragging and dropping from other windows (the editor window or C watch
window).
Drag and drop
(6) After the items have been added, the access history reference area will display the history of access to the variables
graphically.
Access history reference area
- On each row, the maximum and minimum values of the specified variable are shown at the left end, and the y
value of the horizontal grid is shown at the right end. The x value (time) of the left end of the current graph is
shown in the bottom left corner.
- The parameters shown at the top of the data trace window indicate, from left to right, the time of the point at the
indicator (Current), the time of the point at the marker (Mark), the grid interval (Grid), and the display scale
(Scale). The green line is the indicator and the blue one is the marker.
- In the access history reference area, you can see the history of access to specified addresses in a chart.
- The indicator location can be linked with the [Trace] window, and you can check the memory values in the
cycle that you are inspecting in the [Trace] window. In addition, the cycle at the indicator can also be displayed in
the [Trace] window.