Graphical Display of Data Trace Results
(9) When analysis starts, the [Analyze trace data] dialog box will appear. Wait for a while. To abort analysis, click on
[Cancel]. If an analysis in progress is cancelled, the data trace window will show data for the range analyzed up to
that point.
REJ06J0048-0100/Rev.1.00 2008.07 Page 12 of 23
4.4 Graphically Displaying Data Trace Results
Next, specify target variables to monitor through the data trace window and to graphically display the access history.
(1) No symbols are registered by default; specify target variables to monitor. Right-click on the [C Watch] tab of the
data trace window and select [Add C Watch].
- Variables can also be specified by dragging and dropping from other windows (the editor window or C
watch window).
- If a local variable is specified, a correct value cannot be displayed. When specifying a file local variable,
be sure to specify it while the variable is within the scope.