Renesas PC7501 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Entwicklungssoftware Renesas PC7501 herunter. M16C Family PC7501 Emulator Application Note Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 23
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Application Note
REJ06J0048-0100/Rev.1.00 2008.07 Page 1 of 23
M16C Family PC7501 Emulator
Graphical Display of Data Trace Results
Overview
The full-spec emulator PC7501 for the M16C family provides a data trace function that analyzes realtime trace
measurement results and graphically displays data access information. This document describes how to graphically
display data access information from data trace results by using the PC7501 emulator.
In the description, a user system with an M16C/60 series microcomputer is connected with the PC7501 emulator. The
contents of this document are applicable to cases there a user system with any microcomputer is used with the PC7501
emulator. Graphical display of data trace results is also available for the M16C and M32C simulator.
Contents
1. Specifications......................................................................................................................................2
2. Functional Descriptions........................................................................................................................ 2
3. Software Preparation............................................................................................................................ 2
3.1 Introduction......................................................................................................................................... 2
3.2 Installing the PC7501 Emulator Software............................................................................................... 2
3.3 Installing Other Necessary Software...................................................................................................... 2
4. Operations...........................................................................................................................................3
4.1 Activating the High-Performance Embedded Workshop.......................................................................... 3
4.2 Opening a Workspace ..........................................................................................................................4
4.3 Acquiring and Analyzing Realtime Trace Data....................................................................................... 8
4.4 Graphically Displaying Data Trace Results .......................................................................................... 12
4.5 Optional Menus ................................................................................................................................. 16
5. Frequently Asked Questions ............................................................................................................... 20
5.1 How can I compare changes in multiple data items? ............................................................................. 20
5.2 How can I check the variable access history when the range between the maximum and minimum values is
wide?........................................................................................................................................................ 20
6. Related Documents ............................................................................................................................ 21
Seitenansicht 0
1 2 3 4 5 6 ... 22 23

Inhaltsverzeichnis

Seite 1 - M16C Family PC7501 Emulator

Application Note REJ06J0048-0100/Rev.1.00 2008.07 Page 1 of 23 M16C Family PC7501 Emulator Graphical Display of Data Trace Results Overview The full

Seite 2

M16C Family PC7501 Emulator Graphical Display of Data Trace Results (4) Next, download the target program; double-click on [Tutorial.x30 - 00000000

Seite 3 - 4. Operations

M16C Family PC7501 Emulator Graphical Display of Data Trace Results (7) Next, open the data trace window; open the [View] menu and select [Trace] a

Seite 4 - 4.2 Opening a Workspace

M16C Family PC7501 Emulator Graphical Display of Data Trace Results (9) When analysis starts, the [Analyze trace data] dialog box will appear. Wait

Seite 5

M16C Family PC7501 Emulator Graphical Display of Data Trace Results (2) The [Add] dialog box will appear. Enter a target variable and click on [OK]

Seite 6

M16C Family PC7501 Emulator Graphical Display of Data Trace Results (4) To delete a specified variable, select the target variable, right-click on

Seite 7

M16C Family PC7501 Emulator Graphical Display of Data Trace Results Watch items can also be added by dragging and dropping from other windows (the

Seite 8

M16C Family PC7501 Emulator Graphical Display of Data Trace Results (7) To delete a specified variable, select the target variable, right-click on

Seite 9

M16C Family PC7501 Emulator Graphical Display of Data Trace Results (1) Analyze Trace Data (see (8) in section 4.3) Analyzes the realtime trace da

Seite 10

M16C Family PC7501 Emulator Graphical Display of Data Trace Results (7) Add... (see (5) in section 4.4) Adds an address or variable in the access

Seite 11

M16C Family PC7501 Emulator Graphical Display of Data Trace Results (12) Change Row Setting... Changes the settings for each row in the access hist

Seite 12

M16C Family PC7501 Emulator Graphical Display of Data Trace Results REJ06J0048-0100/Rev.1.00 2008.07 Page 2 of 23 1. Specifications The data trace

Seite 13

M16C Family PC7501 Emulator Graphical Display of Data Trace Results This is the end of the explanation on graphically displaying the data trace resu

Seite 14

M16C Family PC7501 Emulator Graphical Display of Data Trace Results REJ06J0048-0100/Rev.1.00 2008.07 Page 21 of 23 6. Related Documents The PC750

Seite 15

M16C Family PC7501 Emulator Graphical Display of Data Trace Results REJ06J0048-0100/Rev.1.00 2008.07 Page 22 of 23 Renesas Website and Customer Sup

Seite 16 - 4.5 Optional Menus

M16C Family PC7501 Emulator Graphical Display of Data Trace Results REJ06J0048-0100/Rev.1.00 2008.07 Page 23 of 23 1. This document is provided

Seite 17

M16C Family PC7501 Emulator Graphical Display of Data Trace Results 4. Operations This section explains how to activate the High-performance Embedd

Seite 18

M16C Family PC7501 Emulator Graphical Display of Data Trace Results 4.2 Opening a Workspace (1) The [Welcome!] dialog box will appear on the High-

Seite 19 - - Masking registered data

M16C Family PC7501 Emulator Graphical Display of Data Trace Results (2) The [Open Workspace] dialog box will appear. When the software from the CD

Seite 20

M16C Family PC7501 Emulator Graphical Display of Data Trace Results (4) After the workspace has opened, operation on the High-performance Embedded

Seite 21 - 6. Related Documents

M16C Family PC7501 Emulator Graphical Display of Data Trace Results (5) The [Init (M16C R8C PC7501 Emulator)] dialog box will appear. In the [MCU]

Seite 22 - Revision History

M16C Family PC7501 Emulator Graphical Display of Data Trace Results (7) After the PC7501 emulator has been successfully connected, operation on the

Seite 23

M16C Family PC7501 Emulator Graphical Display of Data Trace Results (2) Build a project to reflect the modifications made in source file Tutorial.c

Kommentare zu diesen Handbüchern

Keine Kommentare