24
R01DS0139ED0100
Data Sheet
Chapter 3 Power supply specification
3.5.4 Condition 5
M2 products only. RESET is not used; PTCTL1 is used
Normal operating mode
Parameter Symbol Condition
Ratings
Unit
Min Typ Max
REG0VDD, REG1VDD, IOVDD (rise) to
PTCTL1 (rise) setup time
tR1PTON - - 1 ms
REG0VDD, REG1VDD, IOVDD (rise) to
CVDD (rise) byPTCTL1 (rise)
tR0CON 1 - 10 ms
REG0VDD, REG1VDD, IOVDD (rise) to
FLMD0,1(VIL) hold time
tR0MDH 2 - - ms
FLMD0,1 (VIL) to REG0VDD,
REG1VDD, IOVDD (fall)
tMDR0OF 0 - - ms
REG0VDD, REG1VDD, IOVDD (fall) to
PTCTL1 (fall)
tR1PTOF - - 1 ms
PTCTL1 (fall) to CVDD (fall) tPTCOF 0 - 8 ms
REG0VDD
REG1VDD
IOVDD
CVDD
FLMD0
P0_1/FLMD1
3.0V
VIL
VIL
tR0CON
1.1V
PTCTL1
tR0MDH
tR1PTON
3.0V
tPTCOF
tMDR0OF
tR1PTOF
Kommentare zu diesen Handbüchern