Renesas Emulation Probe for M32C/87 Group M30870T-EPB Bedienungsanleitung Seite 26

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 106
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 25
M30870T-EPB User’s Manual 2. Setup
R20UT0209EJ0400 Rev.4.00 Page 26 of 106
Aug 16, 2012
2.6 Turning ON the Power
2.6.1 Checking the Connections of the Emulator System
Before turning the power ON, check the co
nnection of the interface cable with host machine, PC7501, emulation probe, and
user system.
2.6.2 Turning ON/OFF the Power
Turn
ON the power of the emulator and user system as simultaneously as possible.
Turn OFF the power of the emulator and user system as simultaneously as possible.
Do not leave either the emulator or user system powered on, because of leakage current the internal circuits may be
damaged.
When turning ON the power again after shutting OFF the power, wait for about 10 seconds.
Notes on Power Supply:
The emulator's pin Vcc is connected to the user system in order to monitor user system voltage. For this
reason, the emulator cannot supply power to the user system. Therefore, provide the user system with
a separate power supply from that of the emulator.
Keep user system power supply voltage within the MCU's specified range (3.0 to 5.5 V).
Do not change user system power supply voltage after power has been activated.
2.6.3 Power Supply to the User System
This emulator cannot s
upply the power to the user system, therefore design your system so that the user system is powered
separately.
The voltage of the user system should be within the following. And do not change the voltage after activating the system.
(1) When JP1 is set as VCC1 = 2:
3.0 V VCC1 = VCC2 5.5 V
(2) When JP1 is set as VCC1 > 2:
4.8 V VCC1 5.2 V
3.0 V VCC2 < VCC1
Seitenansicht 25