Renesas Emulator System E8 Bedienungsanleitung Seite 137

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 166
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 136
The PC breakpoint that has been set is displayed in the [Eventpoint] window.
Figure 6.31 [Eventpoint] Window (PC Breakpoint Setting)
To stop the tutorial program at the PC breakpoint, the following procedure must be executed:
Close the [Eventpoint] window.
Set the program counter value (PC = H’0E6C6) that was set in section 6.8, Setting Registers,
in the [Register] window. Click the [Go] button.
If program execution is failed, reset the device and execute again the procedures above.
The program runs, and stops at the set PC breakpoint.
Figure 6.32 [Source] Window at Execution Stop (PC Break)
119
Seitenansicht 136
1 2 ... 132 133 134 135 136 137 138 139 140 141 142 ... 165 166

Kommentare zu diesen Handbüchern

Keine Kommentare