To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C
IV State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages,
V SAFETY PAGE READ FIRST • READ this user's manual before using this emulator product. • KEEP the user's manual handy for future reference.
VI means WARNING or CAUTION. Example: CAUTION AGAINST AN ELECTRIC SHOCK means PROHIBITION. Example: DISASSEMBLY PROHIBITED means A FORCIBLE ACTI
VII WARNING Warnings for AC Power Supply: • If the attached AC power cable does not fit the receptacle, do not alter the AC power cable and do no
VIII WARNING • If you smell a strange odor, hear an unusual sound, or see smoke coming from this product, then disconnect power immediately by unp
IX CAUTION Cautions for AC Adapter: • Use only the AC adapter included in this product package. • The included AC adapter is for this emulator. D
X WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emul
i Preface The R0E571490CFK00 is a user system interface board that connects a user system for the SH7149 PLQP0100KB-A (former code: FP-100UV) package
ii
iii Contents Section 1 Configuration ...1 Section 2 Environment
Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang
iv
1 Section 1 Configuration Figure 1 and table 1 show the configuration and components of the user system interface board for the PLQP0100KB-A (forme
2 CAUTION Use a NQPACK100SD-ND socket (manufactured by Tokyo Eletech Corporation) and a HQPACK100SD (manufactured by Tokyo Eletech Corporation) f
3 Section 2 Environmental Conditions Maintain the conditions in table 2 when using the emulator. Table 2 Environmental Conditions Item Specificati
5 Section 3 User Interface Specifications This user system interface board has the function that masks the chip select signals (CS0 and CS1), bus r
6 Table 3 Setting a Switch (SW1) Switch Setting SW1 No. PLQP0100KB-A (Former Code: FP-100UV) Socket Pin No. Signal Name On Off 1
7 Section 4 Connection Procedures 4.1 Connecting User System Interface Board to User System WARNING Always switch OFF the user system and the
8 4.1.2 Installing Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a PLQP0100KB-A (former code
9 BoardScrews (M2.0 x 10 mm)User systemIC socket(NQPACK100SD-ND manufactured by Tokyo Eletech Corporation)Pin 1 Figure 4 Connecting User System Int
SH7149 Group PLQP0100KB-AUser System Interface BoardUser’s ManualUser’s Manual Rev.5.00 2007.02Renesas Microcomputer Development Environment SystemS
10 4.2 Connecting User System Interface Board to EV-Chip Board WARNING Observe the precautions listed below. Failure to do so will result in
11 BoardSpacerUser systemEV-chip unitConnector No.User I/F Connector 1(CN4)EV-Chip Unit Connector No.Board Connector No.UCN1UCN2User I/F Connector 2(
12 4.3 Recommended Dimensions for User System Mount Pad (Footprint) Figure 6 shows the recommended dimensions for the mount pad (footprint) for the
13 4.4 Dimensions for External Bus Trace Unit, Emulation Memory Unit, EV-Chip Unit, and User System Interface Board The dimensions for the external
14 125.090.090.045.05.0125.090.0110.020.030.060.05.0125.090.0Unit: mmTolerance: ±0.5 mmExternal bus trace unitBoardSpacerEV-chip unitPin 1Emulation m
15 4.5 Resulting Dimensions after Connecting User System Interface Board The resulting dimensions, after connecting the user system interface board
16 24.542.112.555.530.037.527.529.2IC socket(NQPACK100SD-ND manufactured by Tokyo Eletech Corporation)User systemPin 1Top viewSpacer (φ6.0)Unit: mmTo
17 24.529.212.542.630.037.527.5EV-chip unitSpacer (φ6.0)IC socket(NQPACK100SD-ND manufactured by Tokyo Eletech Corporation)User systemUnit: mmToleran
19 Section 5 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver
20 MCU (SH7149)Screws (M2.0 x 6 mm)Socket coverPin 1User systemIC socket (NQPACK100SD-ND manufactured by Tokyo Eletech Corporation) Figure 11 Insta
21 Section 6 Verifying Operation 1. Turn on the emulator according to the procedures described in the SH-2A, SH-2 E200F Emulator User's Manua
23 Section 7 Notice 1. Before connecting any parts or cables, make sure that pin 1 on the both sides are correctly aligned. 2. Do not apply exces
24
SH7149 Group PLQP0100KB-A User System Interface BoardUser's Manual Publication Date: Rev. 1.00, December 10, 2004
Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japanhttp://www.renesas.comRefer to
1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanSH7149 Group PLQP0100KB-AUser System Interface BoardREJ10J1213-0500User’s Manual
1. This document is provided for reference purposes only so that Renesas customers may select the appropriate Renesas products for their use
I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this emulator product. • KEEP the user's manual handy for future
II Target User of the Emulator Product: This emulator product should only be used by those who have carefully read and thoroughly understood th
III LIMITED WARRANTY Renesas warrants its emulator products to be manufactured in accordance with published specifications and free from d
Kommentare zu diesen Handbüchern