H8S/2655 Series TQFP-120 User System Interface Cable (HS2655ECN61H) for E6000 Emulator User’s Manual HS2655ECN61HE(C)
6 2.2.2 Soldering IC Socket After fastening, solder the IC socket for a TFP-120 package to the user system. Be sure to completely solder the leads
Fasten the user system interface cable head to the IC socket for a TFP-120 package on the user system with the four screws (M2 x 12 mm; with four flat
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable bodyCable headRemove jigPush the remove jigRemovingUser systemFigure 4
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Figure 6 Dime
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head
12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdrive
MCUPin 1IC socket (IC149-120-043-B5manufactured by YAMAICHI ELECTRONICS Co., Ltd.)User systemScrews (M2 x 8 mm) with flat washersSocket cover Figure 8
Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2655 series, turn on the emulator according to the procedures described
Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable
Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intel
6. The JP1 jumper connector is used for testing. Do not remove the inserted jumper pin. JP1 Figure 11 JP1 Jumper Connector 16
i Preface Thank you for purchasing this user system interface cable (HS2655ECN61H) for the Renesas’s original microcomputer H8S/2655 series. The HS26
ii Contents Section 1 Configuration...1 Section 2 Connection Pr
1 Section 1 Configuration CAUTION Use an IC149-120-043-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the TFP-120 package
Figure 1 HS2655ECN61H User System Interface Cable 2
3 Table 1 lists the HS2655ECN61H components. Please make sure you have all of these components when unpacking. Table 1 HS2655ECN61H Components No.
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. F
Emulator stationE6000Cable bodyUser system interface cable Figure 2 Connecting User System Interface Cable to Emulator Station 2.2 Connecting User