( 35 / 72 )
Figure 3.13 Foot patterns of A-D conversion bypass capacitor
IMPORTANT
Note on the A-D Converter:
Because a flexible board and other devices are used between the emulator MCU and
the target system, the A-D converter operates differently from the actual MCU.
Make the final evaluation of the A-D converter using the actual MCU.
3.5 A-D Conversion Bypass Capacitor
Figure 3.13 shows the foot pattern of the A-D conversion bypass capacitor. The emulation pod has
foot patterns between AVCC and AVSS (C54) on the reverse side of the M306V0T-PRT for mounting
a bypass capacitor. Mount a suitable bypass capacitor as occasion demands.
AVCC-AVSS bypass capacitor