MITSUBISHI MICROCOMPUTERS
3802 Group
SINGLE-CHIP 8-BIT CMOS MICROCOMPUTER
29
Fig. 28 Timing of reset
RESET
Data
φ
Address
SYNC
X
IN
: 8 to 13 clock cycles
X
IN
?
?
??
?
FFFC FFFD
AD
H
, AD
L
?
??
?
?
AD
L
AD
H
1: f(X
IN
) and f(φ) are in the relationship: f(X
IN
)=2
•
f(φ).
2: A question mark (?) indicates an undefined status that depends on the previous status.
Reset address from the vector table
Notes
?
?