7.10.14 Specify the write condition
Trace data write conditions can be specified.
You can specify the following write conditions:
1. Write conditions unlimited (default)
2. Cycles from the start event established to the end event established
3. Only cycles where the start event is established
4. Cycles from the start event established to the start event unestablished
5. Other than cycles from the start event established to the end event established
6. Other than cycles where the start event is established
7. Other than cycles from the start event established to the start event unestablished
To specify condition 1, choose "Total" from the list box of the window's "Write Condition" item.
To specify conditions 2 to 4, choose "Pick Up" and click the "Detail..." button to open the
"Realtime-trace Write Condition" dialog box.
For condition 2, choose the Mode shown below and set the Start and End events.