14
2.2.5 Notes on Setting the [Break Condition] Dialog Box and BREAKCONDITION_SET
Command
1. When [Go to cursor], [Step In], [Step Over], or [Step Out] is selected, the settings of Break
Condition 4 are disabled.
2. Break Condition 4 is disabled when an instruction to which a BREAKPOINT has been set is
executed. Accordingly, do not set a BREAKPOINT to an instruction which satisfies Break
Condition 4.
3. When a Break Condition is satisfied, emulation may stop after two or more instructions have
been executed.
4. If a PC break address condition is set to the slot instruction after a delayed branch instruction,
user program execution cannot be terminated before the slot instruction execution; execution
stops before the branch destination instruction.
5. Settings of BREAKPOINT and Break Condition 1,2,3,4 are disabled while the STEP OVER
function is being used.