Sequential Setting: Using the [Combination action (Sequential or PtoP)] dialog box specifies the
sequential condition and the start or end of performance measurement.
Table 2.10 Conditions to Be Set
Classification Item Description
[Ch1, 2, 3] list box Sets the sequential condition and the start or end of performance
measurement using Event Conditions 1 to 3 and 11.
Don’t care Sets no sequential condition or the start or end of
performance measurement.
Break: Ch3-2-1 Breaks when a condition is satisfied in the order of
Event Condition 3, 2, 1.
Break: Ch3-2-1,
Reset point
Breaks when a condition is satisfied in the order of
Event Condition 3, 2, 1.
Enables the reset point of Event Condition 11.
Break: Ch2-1 Breaks when a condition is satisfied in the order of
Event Condition 2, 1.
Break: Ch2-1,
Reset point
Breaks when a condition is satisfied in the order of
Event Condition 2, 1.
Enables the reset point.
I-Trace stop: Ch3-2-1 Setting is disabled in this MCU.
I-Trace stop: Ch3-2-1,
Reset point
Setting is disabled in this MCU.
I-Trace stop: Ch2-1 Setting is disabled in this MCU.
I-Trace stop: Ch2-1,
Reset point
Setting is disabled in this MCU.
Ch2 to Ch1 PA Sets the performance measurement period during
the time from the satisfaction of the condition set in
Event Condition 2 (start condition) to the
satisfaction of the condition set in Event Condition
1 (end condition).
Ch1 to Ch2 PA Sets the performance measurement period during
the time from the satisfaction of the condition set in
Event Condition 1 (start condition) to the
satisfaction of the condition set in Event Condition
2 (end condition).