2. Emulator mode Tab
The selection of the device, the specification of the mode, and the setting of the power supply are done in the [Emulator
mode] tab of the [Emulator Setting] dialog box.
Figure 6.2 [Emulator mode] Tab
[Device]
Select the name of the MCUs to be used from the [Device] drop-down list box.
[Mode]
-
Erase Flash and Connect
When starting up the debugger, erase the flash memory data of the MCUs. The program for the E8 emulator is
written at the same time.
- Keep Flash and Connect
When starting up the debugger, keep the flash memory data of the MCUs. Note that the area for the E8
emulator program and the E8 emulator used vector area will be changed.
-
Program Flash
Select this mode when using the E8 emulator as a simple programmer. On downloading write only the user
program (The program for the E8 emulator is not written). Therefore, the program cannot be debugged in this
mode.
[Power supply]
When [Power Target from E8. (MAX 300mA)] is checked, power will be supplied to the user system up to 300mA.
Note that when debugging the system which operates the MCU with dual-power supply, the power cannot be
supplied from the E8.
3.
Firmware Location Tab
For details, see “1. Program area for the E8 emulator” and “7. Debugging of the watchdog timer” of the “Section 5.
Notes on Using the E8 Emulator”.
24