Note on RESET* Input:
• The reset input from the target system is accepted only while a user program is being executed (only
while the RUN status LED on the PC4701's front panel is lit).
IMPORTANT
Note on When Starting Up the Emulator Debugger:
• With the M30100T-RPD-E, it is necessary to execute the following when starting up the emulator
debugger. Otherwise, the M30100T-RPD-E may not operate properly.
Custom command
Execute custom command RESET_10 every time you start up the emulator debugger.
• When you execute custom command RESET_10, if "RESET_10 is done!" is displayed instead of
"RESET_10 (Ver.2) is done!", a custom command program file of a previous version is used.
Replace the old custom command program file reset_10.p with the "reset_10.p" file in the floppy
disc included with this product, and re-execute custom command RESET_10.
Note on Clock Supply to the MCU:
• Clock can be supplied to the evaluation MCU in one of the following two ways. This is determined
by emulator debugger clock selection.
(1) When Internal is selected:
The clock generated by the oscillation circuit in the emulation pod is supplied to the evaluation
MCU. The clock is continually supplied to the evaluation MCU regardless of "target system
clock status" and "user program execution status".
(2) When External is selected:
Clock supply to the evaluation MCU depends on oscillation status (oscillate/off) of the target
system.
• It is necessary to use an oscillation circuit board with this product.
Notes on MAP References and Settings:
• For details on referencing and setting MAP information, see the user's manual of emulator
debugger M3T-PD30.
• The initial map settings of this product are as shown below. Use this product with the initial settings.
00000h--003FFh: "EXT"
00400h--FFFFFh: "INT"