2.7 Connecting the E200F External Bus Trace Unit with the User System
To use the external bus trace function in the emulator, the emulator and the user system must be
connected via the external bus trace unit (R0E0200F1ETU00). Install the connector on the user
system for connection of the external bus trace unit, referring to section 2.8, Installing the External
Bus Trace Unit Connector, in this manual. When designing the user system, read the SH-2A, SH-2
E200F Emulator User's Manual and hardware manual for the related MCU.
2.8 Installing the External Bus Trace Unit Connector
2.8.1 External Bus Trace Unit Connector Installed on the User System
Table 2.3 shows the recommended external bus trace unit connector.
Table 2.3 Recommended Connector
Type Number Manufacturer Specification
QTH-090-04-L-D-A Samtec, Inc. QTH series, 0.5-mm pitch, 180 pins
Note: Do not place any components within 6 mm of the external bus trace unit connector.
2.8.2 Pin Assignments of the User System Connector
Pin assignment on the user system (connector is installed)
Probe direction
179
180
1
2
Figure 2.12 Pin Assignments of the User System Connector