Renesas H8S/2111B Bedienungsanleitung Seite 559

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 582
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 558
Rev. 1.00, 05/04, page 525 of 544
Table 22.9 I
2
C Bus Timing
Conditions: V
CC
= 3.0 V to 3.6 V, V
SS
= 0 V, φ = 5 MHz to maximum operating frequency,
T
a
= –20 to +75°C
Ratings
Item Symbol Min. Typ. Max. Unit
Test
Conditions
Notes
SCL input cycle time t
SCL
12 — — t
cyc
SCL input high pulse width t
SCLH
3 — — t
cyc
SCL input low pulse width t
SCLL
5 — — t
cyc
SCL, SDA input rise time t
Sr
7.5* t
cyc
SCL, SDA input fall time t
Sf
300 ns
SCL, SDA input spike pulse
elimination time
t
SP
1 t
cyc
SDA input bus free time t
BUF
5 — — t
cyc
Start condition input hold time t
STAH
3 — — t
cyc
Retransmission start condition
input setup time
t
STAS
3 — — t
cyc
Stop condition input setup time t
STOS
3 — — t
cyc
Data input setup time t
SDAS
0.5 — — t
cyc
Data input hold time t
SDAH
0 — — ns
SCL, SDA capacitive load C
b
400 pF
Figure
22.22
Note: * 17.5 t
cyc
can be set according to the clock selected for use by the I
2
C module. For
details, see section 13.6, Usage Notes.
Seitenansicht 558
1 2 ... 554 555 556 557 558 559 560 561 562 563 564 ... 581 582

Kommentare zu diesen Handbüchern

Keine Kommentare