7.10.9 Set the Measurement Condition
For the debugger, the following measurement conditions can be specified.
Measure the execution time between the events.
Measure a period at which intervals events occur.
Measure the time at which events are established.
By specifying a function name, it is possible to measure the execution time of that function. Up to four
measurement intervals can be specified. To specify measurement intervals, click any line (MP1-MP4)
in the Measurement Point group of the Interval Time Measure Window. This opens a dialog box for
specifying measurement conditions.
7.10.9.1 Measure the execution time between the events
1. Set the measurement events (measurement start event and measurement end event).
2. Specify the following in the Measurement Condition Designation dialog.