2004.1.29 H8S/2628 Group FP-100B User System Interface Cable HS2628ECH61H User’s Manual Renesas Microcomputer Development Environment System Rev.4
1 Section 1 Configuration CAUTION Use an IC149-100-054-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100B package
2 Table 1 lists the HS2628ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS2628ECH61H Components No.
3 Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below.
4 Emulator stationE6000Cable body connectorUser system interface cable Figure 2 Connecting User System Interface Cable to Emulator Station
5 2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USE
6 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-100B package on the u
7 Fasten the user system interface cable head to the IC socket for an FP-100B package on the user system with the four screws (M2.6 x 12 mm; with fou
8 2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable bodyCable headRemove jigPush two remove jigs.RemovingUser system Figure
9 2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system w
10 2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Uni
Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better an
11 2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable
12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver
13 MCUPin 1IC socket (IC149-100-054-B51manufactured by YAMAICHI ELECTRONICS Co., Ltd.)User systemScrews (M2.6 x 6 mm) with flat washersSocket cover F
14 Section 4 Verifying Operation 1. Turn on the emulator according to the procedures described in the H8S Family E6000 Emulator User's Manual
15 Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the ca
H8S/2628 Group FP-100BUser System Interface Cable HS2628ECH61H User's ManualPublication Date: Rev.4.00, Janu
H8S/2628 Group FP-100B User System Interface Cable HS2628ECH61H User’s Manual REJ10B0084-0400H
I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy
II LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and free
III State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so
IV SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for futur
V WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emul
i Preface Thank you for purchasing this user system interface cable (HS2628ECH61H) for the Renesas’ original microcomputer H8S/2628 group. The HS2628
ii Contents Section 1 Configuration.....................1 Section 2 Connection Pr
Kommentare zu diesen Handbüchern