Renesas M30220TF-PRB Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Renesas M30220TF-PRB herunter. Renesas M30220TF-PRB User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 56
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Seitenansicht 0
1 2 3 4 5 6 ... 55 56

Inhaltsverzeichnis

Seite 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Seite 2

( 8 / 54 )Chapter 1. Precautions for SafetyIn both the user's manual and on the product itself, several icons are used to insure proper handlingo

Seite 3 - M30220TF-PRB

( 9 / 54 )IMPORTANTNote on Final Evaluation:• Be sure to evaluate your system and make final confirmation with an CS (Commercial Sample)version MCU.No

Seite 4 - ( 2 / 54 )

( 10 / 54 )IMPORTANTNote on Clock Supply to the MCU:• Clock can be supplied to the evaluation MCU in one of the following two ways. This is determined

Seite 5 - To use the product properly

( 11 / 54 )IMPORTANTNotes on Referencing and Setting the Work Area:• When using this product, set a start address of the work area to "2C00h"

Seite 6 - Contents

( 12 / 54 )MEMO

Seite 7 - ( 5 / 54 )

( 13 / 54 )Chapter 2. PreparationThis chapter describes the package components, the system configuration and the preparation for using this product fo

Seite 8 - Terminology

( 14 / 54 )Chapter 2. Preparation2.1 Package ComponentsThis product consists of the following items. When unpacking, check to see if your product pack

Seite 9 - ( 7 / 54 )

( 15 / 54 )2.3 System ConfigurationFigure 2.1 System configurationProduct (1) shown in Figure 2.1 is this product. Get (2) to (4) separately.(1) Pod p

Seite 10 - CAUTION

( 16 / 54 )MEMO

Seite 11

( 17 / 54 )Chapter 3. Setting UpThis chapter describes switch settings required for using this product and how to connect this product to the PC4701 a

Seite 12

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Seite 13

( 18 / 54 )Figure 3.1 Positions of the switches and their factory-settingsChapter 3. Setting UpWith this product, it is necessary to set the following

Seite 14 - ( 12 / 54 )

( 19 / 54 )Switch No. Switch settingFunctionCNVSSJP1When connecting CNVSSto the target system (Factory-setting)Applies the VCC voltage toCNVSS. When n

Seite 15 - Chapter 2. Preparation

( 20 / 54 )3.2 A-D Conversion Bypass CapacitorThis product has foot patterns on the board for mounting a bypass capacitor for the A-D convertercircuit

Seite 16

( 21 / 54 )Figure 3.4 Removing pod probe M30220TF-PRB(1) Unscrew the two screws of the M30220TF-PRB.(2) Remove the M30220TF-PRB from the FLX64-PRB. In

Seite 17 - 2.3 System Configuration

( 22 / 54 )3.4 Connecting the Target SystemThere are three ways available to connect this product to target system as shown in Figure 3.5.Figure 3.5 C

Seite 18 - ( 16 / 54 )

( 23 / 54 )Figures 3.6, 3.7 and 3.8 show how to connect the pitch converter board FLX-144NSD for 144-pin0.5-mm-pitch package, how to connect the pitch

Seite 19 - Chapter 3. Setting Up

( 24 / 54 )Figure 3.7 Connecting the pitch converter board FLX-144NSE for 144-pin 0.4-mm-pitch TQFP(1) Mount the NQPACK144SE included in the FLX-144NS

Seite 20

( 25 / 54 )Figure 3.8 Connecting the pitch converter board FLX-120NSE for 120-pin 0.4-mm-pitch LQFPCAUTIONNote on Connecting the Target System:• Take

Seite 21

( 26 / 54 )3.5 Procedure for Making an MCU File for M3T-PD30It is necessary to change the contents of the MCU file according to the MCU to be develope

Seite 22

( 27 / 54 )Chapter 4. Debugging Procedure for CPU Rewrite ModeThis chapter describes procedure for debugging the control program for CPU rewrite mode

Seite 23 - When Connecting Pod Probe:

M30220TF-PRBUser’s ManualUser’s ManualRev.1.00 2003.09Pod Probe for M30220 and M30221 Group MCUs

Seite 24 - ( 22 / 54 )

( 28 / 54 )Chapter 4. Debugging Procedure for CPU Rewrite Mode4.1 Outline of Debugging ProcedureYou can use the flash memory in the evaluation MCU on

Seite 25

( 29 / 54 )4.2 Using Custom Commands dbg_reset and fmcr1setThe custom commands dbg_reset and fmcr1set must be used when debugging in CPU rewrite mode.

Seite 26

( 30 / 54 )(2) Custom Command fmcr1setWhen setting "1" in the CPU rewrite mode select bit (FMCR1) (bit 1 of the flash memory controlregister

Seite 27

( 31 / 54 )Custom command fmcr1set specificationsInput format: fmcr1setFunction: fmcr1set writes the instruction to write "0" and the instru

Seite 28 - ( 26 / 54 )

( 32 / 54 )4.3 Debugging Procedure(1) Debugging Procedure for CPU Rewrite Mode (Microcomputer Mode)Here following describe the debugging procedure in

Seite 29 - ( 27 / 54 )

( 33 / 54 )Table 4.1 lists how to set breakpoints for procedures 1 and 3.Table 4.1 How to set breakpoints for procedures 1 and 3CAUTIONNote on Address

Seite 30

( 34 / 54 )(2) Debugging Procedure for CPU Rewrite Mode (Boot Mode)Here following describe the debugging procedure in boot mode. Figure 4.3 shows the

Seite 31 - (1) Custom Command dbg_reset

( 35 / 54 )Table 4.3 lists how to set breakpoints for procedures 1 and 3.Table 4.3 How to set breakpoints for procedures 1 and 3CAUTIONNote on Address

Seite 32 - (2) Custom Command fmcr1set

( 36 / 54 )4.4 How to Access Flash Memory AreaWhen flash memory is enabled (MAP setting for addresses E0000h to FFFDFh is "EXT" and CPUrewri

Seite 33 - ( 31 / 54 )

( 37 / 54 )4.5 Precautions for CPU Rewrite ModeHere following are precautions and restrictions for debugging the control program for CPU rewrite mode.

Seite 34 - 4.3 Debugging Procedure

( 2 / 54 )• NQPACK, YQPACK and YQ-GUIDE are products of Tokyo Eletech Corporation.Keep safety first in your circuit designs!• Renesas Technology Corpo

Seite 35

( 38 / 54 )IMPORTANTNotes on Setting Software Breaks:• When setting software breaks in the control program for CPU rewrite modetransferred to the RAM

Seite 36

( 39 / 54 )IMPORTANTNote on Number of Program/Erase:•Flash memory is capable of 100 program/erase operations. If you are performingmore than 100 progr

Seite 37

( 40 / 54 )MEMO

Seite 38 - (2) Using the Dump Window

( 41 / 54 )Chapter 5. SpecificationsThis chapter describes specifications of this product.5.1 Specifications ...

Seite 39

( 42 / 54 )Chapter 5. Specifications5.1 SpecificationsTable 5.1 lists the specifications of the M30220TF-PRB.Table 5.1 Specifications of the M30220TF-

Seite 40

( 43 / 54 )5.2 External Dimensions(1) External Dimensions of the Pod ProbeFigure 5.1 External dimensions of the M30220TF-PRB(2) External Dimensions of

Seite 41

( 44 / 54 )(3) External Dimensions of the Converter Board (FLX-144NSE)Figure 5.3 shows the external dimensions and a sample foot pattern of the pitch

Seite 42 - ( 40 / 54 )

( 45 / 54 )Chapter 6. TroubleshootingThis chapter describes how to troubleshoot when this product does not work properly.6.1 When the Emulator Debugge

Seite 43 - Chapter 5. Specifications

( 46 / 54 )Chapter 6. TroubleshootingWhen this product does not work properly, check the following.For the latest FAQs, refer to the URL below.http://

Seite 44

( 47 / 54 )(2) Errors Occur When Starting Up the Emulator Debugger(When the target system is connected)Table 6.2 Checkpoints of errors when starting u

Seite 45 - 5.2 External Dimensions

( 3 / 54 )PrefaceThe M30220TF-PRB is a pod probe for flash memory rewrite mode debug of the M30220 andM30221 Group of Renesas 16-bit MCUs. The M30220T

Seite 46 - ( 44 / 54 )

( 48 / 54 )(3) Errors Occur When Starting Up the Emulator Debugger(When the target system is not connected)Table 6.3 Checkpoints of errors when starti

Seite 47 - Chapter 6. Troubleshooting

( 49 / 54 )Chapter 7. Maintenance and WarrantyThis chapter describes how to maintenance, repair provisions and how to request for repair.7.1 Maintenan

Seite 48

( 50 / 54 )Chapter 7. Maintenance and Guarantee7.1 MaintenanceIf dust or dirt collects on any equipment of your emulation system, wipe it off with a d

Seite 49

( 51 / 54 )7.4 How to Request for RepairIf your product is found faulty, follow the procedure below to send your product for repair.Customer Fill in t

Seite 51 - ( 49 / 54 )

M30220TF-PRB User's ManualRev.1.00September 1, 2003REJ10J0280-0100ZCOPYRIGHT ©2003 RENESAS TECHNOLOGY CORPORATIONAND RENESAS SOLUTIONS CORPORATIO

Seite 52 - 7.3 Repair Provisions

1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanM30220TF-PRBREJ10J0280-0100ZUser’s Manual

Seite 53 - 7.4 How to Request for Repair

( 4 / 54 )ContentsTerminology ...

Seite 54 - ( 52 / 54 )

( 5 / 54 )Chapter 6. Troubleshooting ...456.1 When the

Seite 55 - REJ10J0280-0100Z

( 6 / 54 )TerminologySome specific words used in this user's manual are defined as follows:Emulator systemThis means an emulator system built aro

Seite 56 - User’s Manual

( 7 / 54 )Chapter 1. Precautions for SafetyThis chapter describes precautions for using this product safely and properly. For precautions for the emul